Comparison

Induction

HPS

Life Hours

60,000 - 100,000

20,000 - 30,000

Re-strike

Instant

5~15 minutes

Lamp Operating Temperature

<80�F
Reduces A/C cost

>350� F
Increased A/C cost

Colour Render Index (Ra)

Approx. 80

Approx. 60

Colour Temperature (K)

3000 - 6500

2000-2200

Flicker

No

Yes

Glare

No

Yes


Luminance Comparison

Light Source

Conventional
lumens per watt

Total lumens (Lm)

Correction
Factor
(P/S ratio)

Pupil Lumens
per watt (Plm/w)

Initial Total (Plm)

40W Induction

70

2,800

1.96

115

4,600

70W HPS

75

6,400

0.57

52

3,648

120W Induction

82

9,600

1.96

157

18,815

250W HPS

93

27,500

0.57

63

15,675

250W Induction

82

20,500

1.96

161

40,180

400W HPS

110

50,000

0.57

72

28,500


Lumen Maintenance Factor Comparison

Light Source

Initial Total ( Plm / w )

Lumen Depre rate at 4,000 hr (%)

Total at 4,000 hr ( Plm / w)

Lumen Depre rate at 12,000 hr (%)

Total at 12,000 hr ( Plm / w ) average

Lumen Depre rate at 24,000 hr (%)

Total at 24,000 hr ( Plm / w ) average

40W Induction

4,600

4

4,416

6

4,324

10

4,140

70W HPS

3,648

10

3,283

25

2,736

35

2,370

150W Induction

18,815

4

18,062

6

17,686

10

16,934

250W HPS

15,675

10

14,108

25

11,756

35

10,190

250W Induction

40,180

4

38,573

6

37,770

10

36,162

400W HPS

28,500

10

25,650

25

21,375

35

18,525


Notes

  • A light working 24/7 in a factory runs for 8,760 hours per year.
  • LightingRetroFit tables are based on matching as closely as possible, the Plm/w as calculated using the S/P ratio formula. We consider this to be the emerging international standard in lighting design.
  • High quality HPS globes can be rated as high as 30,000 hours (3 changes per Induction globe life). Lesser quality, cheaper globes may be rated as low as 12,000 hours (8 changes per Induction globe life). Download and use our cost savings charts to quantify your long term re-lamping and maintenance costs.
  • When considering changes to facility lighting one should consider whether the existing lighting is adequate for the current use in different areas of the plant. Refitting with LightingRetrofit parts allows the client to increase, decrease or change the colour temperature (K) of their current lighting levels in line with their actual lighting requirements.
  • The lighting maintenance level for induction lighting beyond 24,000 hours remains steady in a range from 90% depleting down to around 80% beyond 80,000 hours.
  • Typically a new High Pressure Sodium globe and ballast would cost from $60-120 depending on quality.